Sulfur-in-Oil Analyzer SLFA-2100/2800

For measuring the new low sulfur fuels, diesel and RFG.

  • repeatability - 1,6 ppm;
  • lower detection limit - 5 ppm;
  • operation using the built-in controller.

The SLFA-2100/2800 are designed specifically to meet the recent demanding needs of measuring the new low sulfur fuels, diesel and RFG.

Using the X-ray fluorescence technique, fast and accurate measurements can be carried out in compliance with the ASTM D4294 method, either in the lab or in the field.

A detection limit of 5 ppm sulfur takes you to new realms of measurement sensitivity. HORIBA's high sensitivity analyzer makes quick, accurate measurements of petroleum fuel samples from very low to high sulfur concentrations - i.e., all the way from gasoline to heavy fuel oils. A large, easy-to-read LCD screen, simple function keys, alphanumeric keypad and other features make the SLFA-2100/2800 Series so easy to use.

The SLFA-2800 has an automated turntable to measure up to eight samples unattended, while the SLFA-2100 is a single-sample version.

Product benefits:
  • Wide measurement range (0-9.999%) is acceptable for very small content as in diesel oil or high sulfur content as in heavy oil;
  • Calibration graphs have been extended and the analyzer selects automatically out of seven scales (0.002/0.01/0.05/…/10%);
  • High precision measurement (Repeatability:1.6ppm, Lower detection limit: 5ppm) Due to the miniature X-ray tube, extremely precise results can be achieved without purging of He or another gas and this system also include a correction function for temperature and atmospheric pressure without He purge;
  • SLFA-2800 is equipped with a turntable, which makes sequential measuring of up to eight samples;
  • Standards applied to device measurement functions: JIS K2541, JIS B7995(Japan), ASTM D4294(USA), ISO 8754.
Characteristic Point

Sample

Sulfur content in petroleum products, such as heavy oil,
naphtha, crude oil, etc.

Range

0 – 9,999 %

Detection limit

5 ppm or less

Accuracy

Less than 5 ppm (with a sample containing 1% sulfur)
Less than 1.6 ppm (with a sample containing 0% sulfur)

Calibration

Calibration made using any standard sample
(2 to 20 calibration points)

Sample requirement

4 – 10 ml

Measurement time

User set from 10 to 600 sec

External output

Printout of results and digital data output (RS-232C interface)

Power supply

100 V AC – 240 V±10%, 50/60 Hz

Power comsumptions

150 VA

Dimensions (WxDxH)

50 х 43 х 25 cm

Mass
- SLFA-2100
- SLFA-2800


21 kg
24 kg